CLDGV - SF96-50, DIMETHYLPOLYSILOXANES

  • MSDS: CLDGV
  • Manufacturer: GE SILICONES
  • Product Name: SF96-50, DIMETHYLPOLYSILOXANES
  • National Stock Number: 9150-00-261-8327
Product Identification

Product ID:SF96-50, DIMETHYLPOLYSILOXANES
MSDS Date:05/19/1994
FSC:9150
NIIN:00-261-8327
Status Code:A
MSDS Number: CLDGV

Responsible Party
GE SILICONES
260 HUDSON RIVER ROAD
WATERFORD, NY 12188
US

Emergency Phone: 518-237-3330

Info Phone: 518-237-3330

Preparer: DA POLSINELLI

Cage: 01139

Contractor
THE SMITH GROUP INC.
PHILADELPHIA, PA 19124-3893 US

Telephone: 215-743-8200

Cage: 2B613

Ingredients

DIMETHYLPOLYSILOXANES (NON-HAZARDOUS)

CAS: 63148-62-9

RTECS: JT6484500

Hazards

LD50 LC50 Mixture:ACUTE ORAL LD50 (MG/KG)= > 40,000
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: NONE KNOWN. SKIN: NONE
KNOWN. INHALATION: NONE KNOWN. EYE: MAY CAUSE MILD EYE IRRITATION.
Explanation of Carcinogenicity:THIS PRODUCT OR ONE OF ITS INGREDIENTS
PRESENT 0.1% OR MORE IS NOT LISTED AS A CARCINOGEN OR SUSPECTED
CARCINOGEN BY NTP, IARC OR OSHA
Effects of Overexposure:NOT PROVIDED BY MFR
Medical Cond Aggravated by Exposure:NONE KNOWN

First Aid

First Aid:INGESTION: NONE KNOWN. SKIN: WASH WITH SOAP AND WATER.
INHALATION: NONE KNOWN. EYE: IN CASE OF CONTACT, IMMEDIATELY FLUSH
EYES WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES AND GET MEDICAL
ATTENTION IF IRRITATION PERSISTS. NOTE TO PHYSICIAN: NONE KNOWN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:=301.7C, 575.F
Autoignition Temp:Autoignition Temp Text:UNK
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:ALL STANDARD FIREFIGHTING MEDIA
Fire Fighting Procedures:WILL NOT OCCUR
Unusual Fire/Explosion Hazard:NOT PROVIDED BY MFR

Accidental Release

Spill Release Procedures:WIPE, SCRAPE OR SOAK UP IN AN INERT MATERIAL
AND PUT IN A CONTAINER FOR DISPOSAL. WASH WALKING SURFACES WITH
DETERGENT AND WATER TO REDUCE SLIPPING HAZARD.
Neutralizing Agent:NOT PROVIDED BY MFR

Handling

Handling and Storage Precautions:NONE KNOWN
Other Precautions:NOT PROVIDED BY MFR

Exposure Controls

Respiratory Protection:NONE KNOWN
Ventilation:NONE KNOWN
Protective Gloves:NONE KNOWN
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE KNOWN
Work Hygienic Practices:NOT PROVIDED BY MFR
Supplemental Safety and Health
NOT PROVIDED BY MFR

Chemical Properties

HCC:N1
Boiling Pt:>204.4C, 400.F
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NOT PROVIDED BY MFR
Vapor Pres:NEG
Vapor Density:NA
Spec Gravity:0.97 (WATER=1)
pH:UNK
Viscosity:NOT PROVIDED BY MFR
Evaporation Rate & Reference:< 1 (BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE (20 DEG C)
Appearance and Odor:CLEAR, LIQUID, ODORLESS
Percent Volatiles by Volume:< 1
Corrosion Rate:NOT PROVIDED BY MFR

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
FORMALDEHYDE
Conditions to Avoid Polymerization:WILL NOT OCCUR

Disposal

Waste Disposal Methods:DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REGULATIONS. INCINERATION RECOMMENDED IN
APPROVED INCINERATOR ACCORDING TO FEDERAL, STATE, AND LOCAL
REGULATIONS.

Toxicology

Toxicological Information:ACUTE ORAL LD50: >40,000 MG/KG. ACUTE DERMAL
LD50: NONE FOUND. ACUTE INHALATION LC50:.>535 MG/L (RAT).
NON-IRRITATING TO SKIN (RABBIT). AMES TEST: UNKNOWN.

Ecology

Ecological:NO DATA AT THIS TIME.

Transport

Transport Information:DOT SHIPPING NAME: NONE

Regulatory

SARA Title III Information:SECTION 302: NONE FOUND. SECTION 311, 312:
NONE. SECTION 313: NONE.
State Regulatory Information:CALIFORNIA PROPOSITION 65: NONE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.